Krieger s 705 scif door and lock package meets scif sound groups 3 and 4 standards and comes with an installed kaba mas sargent and greenleaf or lockmasters locking device.
Scif door requirements.
Requirements for scif door assemblies by scott detienne ra ccs bscp cpp ahc code corner t his article provides general require ments for standard door frame and hardware components door assemblies and related construction items utilized for scif s based on dcid.
The first scif door locks to have a chamfered bolt designed to provide smooth non binding entry into the strike plate.
Scif doors must be solid wood core or a specially constructed door filled with sound attenuation material of stc 45 rating or higher.
Scif construction differs greatly from traditional construction and the current version of the tech spec has 174 pages of specific guidelines that cover everything from wall materials to ductwork to the type of hardware you can have on the scif doors.
Door frame hinges closer locking device threshold door bottom and seal system.
3 3 3 3 all scif primary entrance doors must be equipped with an automatic door closer a gsa approved combination lock and an access control device with the following requirements.
In the case of retrofitting an existing room to scif specifications even wood fillers must meet sound suppression requirements.
Compartmented information facilities ics 705 1 and standards for accreditation and reciprocal use of sensitive compartmented information facilities ics 705 2 and supersedes director of central intelligence directive dcid 6 9.
One of our qualified customer service representatives will contact you.
The only single motion egress scif door locks currently available that fully meet the updated requirements of gsa ff l 2890bc regulations.
Sound sealing door gaskets and door sets must also be rated at a minimum of stc45.
If doors are equipped with hinge pins located on the exterior side of the door where it opens into an uncontrolled area outside the scif the hinges will.
If a scif or sapf cannot be accredited.
A scif or sapf is established when there is a clear operational requirement that is crucial to the command s mission.
The specifications contained herein will facilitate the protection of sensitive compartmented.
In order to offer end users information concerning upgrading existing scif s or building new scif s we conduct technical seminars that cover the rules and.
To be operational a scif or sapf must be accredited.
Ask about our 24 hour door program 2 week door program or specialty rf bullet blast security doors hm wd.
Accreditation is the formal approval that a space meets the prescribed physical technical and operational standards.